WinDaqStarter Kit DI-194

All the info provided here is "AS IS", please do not email DATAQ for further support/explanation

 If you have questions regarding programming this device, click here.
(Samples in various programming languages are available)

  B7 B6 B5 B4 B3 B2 B1 B0
Byte1 A0 0 0 0 D2 D1 D0 0
Byte2 A7 A6 A5 A4 A3 A2 A1 1
Byte3 B0 0 0 0 D2 D1 D0 1
Byte4 B7 B6 B5 B4 B3 B2 B1 1
Byte5 C0 0 0 0 D2 D1 D0 1
Byte6 C7 C6 C5 C4 C3 C2 C1 1
Byte7 E0 0 0 0 D2 D1 D0 1
Byte8 E7 E6 E5 E4 E3 E2 E1 1
Note Ax is the xth bit of ADC reading from channel one
Bx is the xth bit of ADC reading from channel two if enabled
Cx is the xth bit of ADC reading from channel three if enabled
Ex is the xth bit of ADC reading from channel four if enabled
Dx is the digital input bits

To program DI-194 under VisualBASIC or LabView, please click here

Commands
Cmd Data Default Action
C 0 thru 15 0 Channels 000 thru 1111
D 0, 1 0 0 = output square wave

1= input

L 0...255 0 Ls byte of counter
M 0...255 0 Ms byte of counter
S 0, 1 0 ADC stop, start
R Z   reset
E key N.A. If you don't have the key when you got the unit, you can purchase it from DATAQ for $15. 
N Z   Return 10 bytes serial number of the device. If you run WinDaq, you can also inqure the serial number from the About dialog box
Send NULL before any command, which can be sent out by keying in <Ctrl-2> under VT100 mode if you are using HyperTerminal